EasyManua.ls Logo

ABB PFEA 113 - 3.12.3 Setting Object Type

ABB PFEA 113
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tension Electronics PFEA113, User Manual
Section 3.12.3 Setting Object Type
3BSE029382R0101 Rev C 3-17
3.12.3 Setting Object Type
Depending on which load cell combination, LoadCellComb:
•one roll
•two rolls or
segmented roll
that is selected in menu “SystemDefinition” the following object types are available.
Figure 3-5. Setting Object Type for One Roll
Use up and down keys to select type of object
[ZZ] from list.
1. StandardRoll (two load cells, A and B connected)
2. SingleSideA (only load cell A connected)
3. SingleSideB (only load cell B connected)
When single side measurement is selected the measured signal is multiplied by two and
presented as web tension on display and analog output.
3.12.3.1 Object Types for One Roll
Figure 3-6. Object Types for One Roll
FastSetUp
WebTension
Presentation-
Menu
SetNominal-
Load
ServiceMenu
ZeroSet
SetWrapGain
> 5 s
AO 1 - AO 6
Miscellaneous
Menu
System-
Definition
ObjectType
DO 1 - DO 4
AI 1 - AI 2
DI
SetObject
ZZ
AreYouSure
SetObject
[ZZ]
To
ObjectType
Setting Object Type for One Roll
SetNominalLoad
Roll 1
A
B
PFEA113
AB
Standard roll
Input
C
D
A
B
PFEA113
AB
Single side A measurement
Input
C
D
A
B
PFEA113
B
Input
C
D
Single side B measurement

Table of Contents