Tension Electronics PFEA113, User Manual
Section D.4 Installation Requirements
3BSE029382R0101 Rev C D-3
D.4 Installation Requirements
To achieve the specified accuracy, the best possible reliability and long-term stability, install the 
load cells in accordance with the requirements below.
Figure D-1. Installation requirements
Max. 0.5°
 Max. 
Web
Alignment of the load cells
Dynamically balanced
Self aligning bearings
Allow axial expansion
Mounting surface 
must be flat within
Stable foundation
If the measuring roll is driven, 
0.1 mm (0.004 in.)
The mounting screws 
by using bearings
with one fixed side
and one loose side
manufacturer´s 
according to the 
shall be tightened 
recommendations
 fulfills at least
measuring roll that
Grade G-2.5 ISO 1940-1
 of disturbances
 a solution with minimized risk
always consult ABB to ensure
(0.12 in./ft)
10 mm/m