KNX control elements and application parameters
Control "Split Unit Control"
Product manual 2CKA001473B5343
161
10.10.17 Step size
Options: 0.5 °C
1.0 °C
1.5 °C
2.0 °C
The parameter is used to set the step size for the temperature measurement in decimal steps of
0.5.
10.10.18 Maximum setpoint [°C]
Options: Setting option from 0 to 40
The parameter is used to specify the maximum adjustable temperature setpoint.
10.10.19 Minimum setpoint [°C]
Options: Setting option from 0 to 40
The parameter is used to specify the minimum adjustable temperature setpoint.