DATABASE MENU ACTWinPro
The timezone assigned to this action determines when the OP3 output is active.
This could be used to control an externally connected device.
AUX Active
The timezone assigned to this action determines when the AUX output is active.
This could be used to control an externally connected device.
PIN Only
The timezone assigned to this action determines when PIN Only operation is in
force for the door. During this time, all card swipes will be ignored: A valid user
PIN must be entered to gain access.
PIN or Card
The timezone assigned to this action determines when either a valid PIN or Card
operation is required to gain entry. During this time, any valid card or PIN must
be entered to gain access.
Twin Users
The timezone assigned to this action determines when two valid cards must be
presented to gain access. This is typically used in high security applications
where two people must be in the room at the same time.
AUX Relay Output
The AUX Output is a programmable output on all door controllers. The various
AUX Output Settings may be checked or unchecked to determine the conditions
for setting this output.
The AUX Output is a programmable output on all door controllers. The various
settings below may be enabled to determine the conditions for activating this
output. It is an open collector output on the ACT1000 (sometimes called the
buzzer output) and is a changeover relay on all other controllers.
Door ajar
Page 51 Access Control Technology