DATABASE MENU ACTWinPro
Elevator Groups
Elevator control is one particular application of the I/O modules (IOM).
ACTWinPro allows programming of users, permitting them access to different
floors in an elevator lift shaft at different times.
The outputs on the IOM are wired into an elevator controller. Up to 32 floors
maybe controlled from a single ACT3000/2000. However controllers maybe
networked giving control of more floors.
Outputs required for elevator control must have the Elevator Floor option
assigned in the I/O module view.
To configure elevator groups, some floor groups must already be assigned.
Assign the Floor Access Rights by selecting the floor group and the timezone
when access is allowed and click the Add button.
A User Group must be created and the Elevator group assigned. This means that
any user with this user group is allowed access to the floors assigned in the
Elevator Group.
A Door must be assigned to a Floor Group. This would be the Door that has the
reader attached in the Elevator Cab. The Floor Group assigned would consist of
all the possible floors that are available from the elevator.
Page 70 Access Control Technology