DATABASE MENU ACTWinPro
Door ajar
A door ajar event is logged if the door has been open for longer than a
predetermined period of time.
Door forced
A door forced event is logged if the door is opened without being explicitly
commanded to open by the controller. This would typically occur if the locking
mechanism is bypassed or if the door is physically forced open.
Read errors
A read error event is logged when an incorrect read occurs on an entry or exit
reader. An additional error number may be displayed giving further details on the
error.
Exit button used
An exit granted (push button) event is logged when a user presses the request-
to-exit (egress) switch.
Door opened
A door opened event is logged when the door is physically opened.
Door closed
A door closed event is logged when the door is physically closed.
Mains fault
Mains fault events are logged. This should be ticked for any doors with a
monitored power supply.
Operation
The operation box contains various Operation Options that may be checked or
unchecked to alter the behaviour of this door.
Anti-tailgate
Normally when a card is swiped, the relay is activated for a pre-determined
period of time. During this period, the door may be physically opened and closed
any number of times as the locking mechanism is disengaged. The anti-tailgate
option truncates the relay time to one second when the door is opened. This
means that the locking mechanism re-engages so the door cannot be reopened
without swiping another card.
Silent operation
Normally the door controller gives an audible success or fail indication when a
card is swiped, in addition to activating the red or green indicator on the reader.
The silent operation option suppresses this audible indication.
Page 53 Access Control Technology