SYSTEM OPTIONS ACTWinPro
This selects a door group that defines the doors that are in the system's
antipassback area. Antipassback operation is local to each controller, so if there
is only one desired antipassback area, these doors must all reside on the same
controller. If the antipassback group includes doors on more than one controller,
then each controller effectively implements a separate independent area.
Perimeter doors
This selects a door group that defines the doors on the perimeter of the
installation. This allows the system to keep track of which users are in or out of
the installation at a given time.
Auto Reset
If this box is checked, then the Time field contains the time of the day when the
antipassback buffer is automatically reset. This ensures that users who failed to
exit properly will be allowed in again. If the box is unchecked, then the
antipassback buffer must be reset manually from the Door Control Dialog.
User Limit A and B
These are user limits that may be used to generate outputs when the number of
users in an area falls below a specified minimum. If user limiting is enabled,
these limits specify the maximum number of users that will be allowed in that
area.
The two limits operate independently. Refer to the controller output options for
details.
Page 73 Access Control Technology