ADT-HC4500 Flame/Plasma Cutting Machine CNC System
- 19 -
Return
2.9.1 Control Interface
While cutting in Auto interface, the system performs preheating before perforation. At this moment, the lower
right of the interface shows the total preheating time and preheated time. In the bottom center, the system prompts:
“To memorize and stop preheating, press [G]; to stop preheating, press [Start]; to extend preheating, press
[Stop]”. According to the prompt, if you press [Start], the system stops preheating immediately and
performs next motion; if you press [Stop], the system will extend the preheating time infinitely; if you
press [G], preheating stops and the system automatically saves current preheating time as the preheating
time later.
In the main menu interface, press [F1] (Auto):
Auto / Speed: / Program name
Prompt:
GTo memorize and stop preheating, press [G]
To stop preheating, press [Start]
To extend preheating, press [Stop]
Ethyne control / Torch up
Preheating control / Torch down
Cutting Control / Height control
Current coordinates
Slot compensation