2-6 i3070 Series 5i Help
Touch Panel Functions
Table  2- 3 Settings
Option Description
Setting 1
Scanner
Press
Long Probe
Retest
Bypass – Skip the action.
Non-Bypass – Perform the action.
This is set via the testplan (except for the Press setting). 
Scan Timeout Time (in seconds) to wait for scan result from the controller 
before triggering an error.
ICT Timeout Time (in seconds) to wait for test result from the controller 
before triggering an error. 
Recontact Timeout Time (in seconds) to wait before retest.
D/Stream Timeout Time (in seconds) to wait for DSB (Downstream Busy) signal 
from downstream machine.
Note: Default timeout = 300 s; minimum 1 s; maximum 999 s.
Setting 2
Jig Height Set the jig height to 75 mm, 85 mm or 100 mm.
DUT Access For systems with optional DUT Access:
Enable or disable access to failed boards.
Board Align Whether to check if the board is seated correctly.
Width Enable or disable automatic conveyor width control. 
Scan on Fly Whether to scan barcode without stopping the board.
DSB RLS Chk Downstream Busy signal release check.