3-2 i3070 Series 5i Help
Test Development
Test Development Overview
Test development on the Medalist i3070 consists of five main tasks listed 
below. Follow the detailed instructions in the Medalist i3070 online help, 
which also explains the use of the software tools you can use in each task. 
During test development, pay attention to the features and requirements 
for the Medalist i3070 Series 5i as described in this chapter.
1 Gather materials and define test strategy.
2 Develop tests and generate fixture files.
During test development, note the following key features for the 
Medalist i3070 Series 5i.
• New “IN-LINE” Keyword 
In the board file, a new keyword is introduced for the Medalist i3070 
Series 5i inline fixture. 
Fixture Type IN-LINE 
Fixture Size BANK2 
• testmain 
When the IN-LINE keyword is used, the new 
testmain_inline will 
be used to generate testplans for the Medalist i3070 Series 5i.
• Fixture Consultant 
When the IN-LINE keyword is used, the graphics display in Fixture 
Consultant is automatically rotated 90 degrees.
The default placement of the board is at the center of the modules 
and toward the front edge of the fixture (see Fixturing Guidelines).
3 Build and verify fixture.
Fixture specifications and requirements for the Medalist i3070 Series 5i 
can be found in Fixturing Guidelines and Fixture Setup and Debugging 
in this chapter.
4 Complete and debug tests.
5 Release to production.