VLL Service Configuration Commands
Page 216 7210 SAS-X, R6 OS Services Guide
meter
Syntax meter meter-id [create]
no meter meter-id
Context config>service>epipe>sap>ingress>meter-override
config>service>vpls>sap>ingress>meter-override
config>service>ies>interface>sap>ingress>meter-override
config>service>vprn>interface>sap>ingress>meter-override
Description This command, within the SAP ingress contexts, is used to create a CLI node for specific overrides to
a specific meter created on the SAP through a sap-ingress QoS policies.
The no form of the command is used to remove any existing overrides for the specified meter-id.
Parameters meter-id — The meter-id parameter is required when executing the meter command within the meter-
overrides context. The specified meter-id must exist within the sap-ingress QoS policy applied to the
SAP. If the meter is not currently used by any forwarding class or forwarding type mappings, the
meter will not actually exist on the SAP. This does not preclude creating an override context for the
meter-id.
create — The create keyword is required when a meter meter-id override node is being created and
the system is configured to expect explicit confirmation that a new object is being created. When the
system is not configured to expect explicit confirmation, the create keyword is not required.
adaptation-rule
Syntax adaptation-rule [pir
adaptation-rule] [cir adaptation-rule]
no adaptation-rule
Context config>service>epipe>sap>ingress>meter-override>meter
config>service>vpls>sap>ingress>meter-override>meter
config>service>ies>interface>sap>ingress>meter-override>meter
config>service>vprn>interface>sap>ingress>meter-override>meter
Description This command can be used to override specific attributes of the specified meter adaptation rule
parameters. The adaptation rule controls the method used by the system to derive the operational CIR
and PIR settings when the meter is provisioned in hardware. For the CIR and PIR parameters
individually, the system attempts to find the best operational rate depending on the defined constraint.
The no form of the command removes any explicitly defined constraints used to derive the
operational CIR and PIR created by the application of the policy. When a specific adaptation-rule is
removed, the default constraints for rate and cir apply.
Default no adaptation-rule
Parameters pir — The pir parameter defines the constraints enforced when adapting the PIR rate defined within
the meter-override meter meter-id command. The pir parameter requires a qualifier that defines