EasyManua.ls Logo

Alcatel-Lucent 7450 - Page 238

Alcatel-Lucent 7450
816 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MPLS Commands
Page 238 7450 ESS MPLS Guide
oam-template
Syntax [no] oam-template name
Context config>router>mpls>mpls-tp
Description This command creates or edits an OAM template Generally applicable proactive OAM parameters
are configured using templates. The top-level template is the OAM template.
Generic MPLS-TP OAM and fault management parameters are configured in the OAM Template.
Proactive CC/CV uses BFD and parameters such as Tx/Rx timer intervals, multiplier and other
session/fault management parameters specific to BFD are configured using a BFD Template, which
is referenced from the OAM template.
Default no oam-template
Parameters name — Specifies a text string name for the template of up to 32 characters in printable 7-bit ASCII,
enclosed in double quotes. Named OAM templates are referenced from the MPLS-TP path MEP
configuration.
hold-time-down
Syntax hold-time-down timer
no hold-time-down
Context config>router>mpls>mpls-tp>oam-template
Description This command configures the hold-down dampening timer. It is equivalent to a hold-off timer.
Default no hold-time-down
Parameters interval — Specifies the hold-down dampening timer interval.
Values 0 — 5000 deciseconds in 10 ms increments
hold-time-up
Syntax hold-time-up timer
no hold-time-up
Context config>router>mpls>mpls-tp>oam-template
Description This command configures the hold-up dampening timer. This can be used to provide additional
dampening to the state of proactive CC BFD sessions.
Default no hold-time-up
Parameters interval — Specifies the hold-up dampening timer interval.
Values 0 — 500 deciseconds, in 100 ms increments
Default 2 seconds