EasyManua.ls Logo

Alcatel-Lucent 7450 - Page 372

Alcatel-Lucent 7450
816 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 372 7450 ESS MPLS Guide
P2MP S2Ls 0 0 0
MPLS-TP LSPs 0 0 0
=======================================================================
*A:Dut-C# show router mpls status
========================================================================
MPLS Status
========================================================================
Admin Status : Down Oper Status : Down
Oper Down Reason : adminDown
FR Object : Enabled Resignal Timer : Disabled
Hold Timer : 1 seconds Next Resignal : N/A
Srlg Frr : Disabled Srlg Frr Strict : Disabled
Dynamic Bypass : Enabled User Srlg Database : Disabled
Least Fill Min Thd.: 5 percent LeastFill ReoptiThd: 10 percent
Short. TTL Prop Lo*: Enabled Short. TTL Prop Tr*: Enabled
AB Sample Multipli*: 1 AB Adjust Multipli*: 288
Exp Backoff Retry : Disabled CSPF On Loose Hop : Disabled
P2mp Resignal Timer: Disabled P2mp Next Resignal : N/A
Sec FastRetryTimer : Disabled Static LSP FR Timer: 30 seconds
P2P Max Bypass Ass*: 1000
P2P Active Path Fa*: 10 P2MP S2l Fast Retr*: 10
ActiveFastRetryTime: Disabled
LSP Counts Originate Transit Terminate
------------------------------------------------------------------------
Static LSPs 0 0 0
Dynamic LSPs 0 0 0
Detour LSPs 0 0 0
P2MP S2Ls 0 0 0
========================================================================
* indicates that the corresponding row element may have been truncated.
*A:Dut-C# /show router mpls status
========================================================================
MPLS Status
========================================================================
Admin Status : Up Oper Status : Up
Oper Down Reason : n/a
FR Object : Enabled Resignal Timer : Disabled
Hold Timer : 1 seconds Next Resignal : N/A
Srlg Frr : Disabled Srlg Frr Strict : Disabled
Dynamic Bypass : Disabled User Srlg Database : Disabled
Least Fill Min Thd.: 5 percent LeastFill ReoptiThd: 10 percent
Short. TTL Prop Lo*: Enabled Short. TTL Prop Tr*: Enabled
AB Sample Multipli*: 1 AB Adjust Multipli*: 288
Exp Backoff Retry : Disabled CSPF On Loose Hop : Disabled
Lsp Init RetryTime*: 30 seconds
P2mp Resignal Timer: Disabled P2mp Next Resignal : N/A
Sec FastRetryTimer : Disabled Static LSP FR Timer: 30 seconds
P2P Max Bypass Ass*: 1000
P2PActPathFastRetry: Disabled P2MP S2L Fast Retry: Disabled
LSP Counts Originate Transit Terminate
------------------------------------------------------------------------
Static LSPs 0 0 0
Dynamic LSPs 3 0 2

Table of Contents

Other manuals for Alcatel-Lucent 7450

Related product manuals