MPLS and RSVP
7450 ESS MPLS Guide Page 41
If an LSP name is provided then the command applies to that specific LSP only and the optional
force parameter (with or without a bandwidth) can be used.
If force is not specified (or the command is not LSP-specific) then measured_bw is compared to
current_bw and bandwidth adjustment may or may not occur
If force is specified and a bandwidth is not provided then the threshold checking is bypassed but
the min and max bandwidth constraints are still enforced.
If force is specified with a bandwidth (in Mbps) then signaled_bw is set to this bandwidth. There
is no requirement that the bandwidth entered as part of the command fall within the range of min-
bandwidth to max-bandwidth.
The adjust-interval, maximum average data rate and overflow count are not reset by the manual
auto-bandwidth command, whether or not the bandwidth adjustment succeeds or fails. The
overflow count is reset only if the manual auto-bandwidth adjustment is successful.