EasyManuals Logo
Home>Allen-Bradley>Controller>MicroLogix 1400

Allen-Bradley MicroLogix 1400 User Manual

Allen-Bradley MicroLogix 1400
694 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #689 background imageLoading...
Page #689 background image
687 Publication 1766-RM001A-EN-P - October 2008
MicroLogix 1400 List of Instructions and Function Files
Instruction List
Instruction- Description Page
ABL - Test Buffer for Line 374
ABS - Absolute Value 206
ACB - Number of Characters in Buffer 375
ACI - String to Integer 376
ACL - ASCII Clear Buffers 367
ACN - String Concatenate 378
ACS - Arc Cosine 220
ADD - Add 205
AEX - String Extract 379
AHL - ASCII Handshake Lines 381
AIC - ASCII Integer to String 368
AND - Bit-Wise AND 257
ARD - ASCII Read Characters 383
ARL - ASCII Read Line 384
ASC - String Search 386
ASN - Arc Sine 218
ASR - ASCII String Compare 387
ATN - Arc Tangent 221
AWA - ASCII Write with Append 369
AWT - ASCII Write 372
BSL - Bit Shift Left 272
BSR - Bit Shift Right 274
CLR - Clear 206
COP - Copy File 269
COS - Cosine 214
CPT - Compute 234
CPW - Copy Word 268
CTD - Count Down 185
CTU - Count Up 185
DCD - Decode 4 to 1-of-16 244
DEG - Radians to Degrees 223
DIV - Divide 205
DLG - Data Log Instruction 525
ENC - Encode 1-of-16 to 4 245
END - Program End 300
EQU - Equal 191
FFL - First In, First Out (FIFO) Load 277
FFU - First In, First Out (FIFO) Unload 279
FLL - Fill File 271
FRD - Convert from Binary Coded Decimal (BCD) 246
GCD - Gray Code 253
GEQ - Greater Than or Equal To 192
GRT - Greater Than 191
HSL - High-Speed Counter Load 130
IIM - Immediate Input with Mask 303
INT - Interrupt Subroutine 312
IOM - Immediate Output with Mask 305
JMP - Jump to Label 297
JSR - Jump to Subroutine 298
LBL - Label 298
LCD - LCD instruction 542
LEQ - Less Than or Equal To 192
LES - Less Than 191
LFL - Last In, First Out (LIFO) Load 282
LFU - Last In, First Out (LIFO) Unload 284
LIM - Limit Test 194
LN - Natural Log 227
LOG - Base 10 Logarithm 229
Memory Module Information Function File 60
MUL - Multiply DIV - Divide 205
NEG - Negate 206
NEQ - Not Equal 191
NOT - Logical NOT 260
ONS - One Shot 171
OR - Logical OR 258
OSF - One Shot Falling 173
OSR - One Shot Rising 173
OTE - Output Energize 169
OTL - Output Latch 170
OTU - Output Unlatch 170
PID - Proportional Integral Derivative 332
PTO - Pulse Train Output 139
PWM - Pulse Width Modulation 158
RAC - Reset Accumulated Value 131
RAD - Degrees to Radians 227
RCP - Recipe 511
REF- I/O Refresh 306
RES - Reset 186
RET - Return from Subroutine 299
RTO - Retentive Timer, On-Delay 181
SBR - Subroutine Label 298
SCL - Scale 208
SCP - Scale with Parameters 209
SIN - Sine 211
SQC- Sequencer Compare 288
SQL - Sequencer Load 294
SQO- Sequencer Output 291
SQR - Square Root 211
STS - Selectable Timed Start 313
SUB - Subtract 205
SUS - Suspend 299
SWP - Swap 286
TAN - Tangent 216
TND - Temporary End 299
TOD - Convert to Binary Coded Decimal (BCD) 250
TOF - Timer, Off-Delay 180
TON - Timer, On-Delay 179
UID - User Interrupt Disable 314
UIE - User Interrupt Enable 315
Instruction List
Instruction- Description Page
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive

Table of Contents

Other manuals for Allen-Bradley MicroLogix 1400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley MicroLogix 1400 and is the answer not in the manual?

Allen-Bradley MicroLogix 1400 Specifications

General IconGeneral
BrandAllen-Bradley
ModelMicroLogix 1400
CategoryController
LanguageEnglish

Related product manuals