Page #126 background imageLoading...
Page #126 background image
User Manual – Rev BE AMETEK Programmable Power
MX Series 126
FUNCTION [3Pi controller only] This field can be used to select the
wave shape to be used during this step of the transient
sequence. Each step can use a different wave shape
from the available library of 50 user-defined waveforms
or the three standard waveforms. The output wave
shape changes upon entry into each step and remains
in effect for the duration of the step. The default wave
shape is always the SINE (sine wave).
REPEAT This is the number of times the SURGE/SAG transient
event will repeat before it proceeds to the next event or
exit the transient program. Note that the number of
times the transient event is generated is equal to the
REPEAT + 1. Leave this value at zero if only one
execution of this event in the list is required.
EVENT # This must be the last item in the transient edit screen.
All data fields must be entered before inserting the
EVENT #. The EVENT # takes a value from 1 to 99. The
EVENT # defines the order of execution of the transient
events in a multiple event transient. It is a good
practice to enter spaced EVENT #’s to allow insertion of
an EVENT later if needed. (For example, space them by
5.) Entry of a sequence EVENT # number will cause
the display to return to the TRANSIENT screen.

Table of Contents

Other manuals for Ametek MX45-3Pi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek MX45-3Pi and is the answer not in the manual?

Ametek MX45-3Pi Specifications

General IconGeneral
BrandAmetek
ModelMX45-3Pi
CategoryPower Supply
LanguageEnglish

Related product manuals