EasyManua.ls Logo

Ametek UPLC-II - Page 178

Ametek UPLC-II
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page C–8
UPLC-II™ System Manual
Recovery Window is a number between the range
o
f 0 – 24 hours. It specifies how long a UPLC-II™
will be in Recovery Mode before indicating a
Delayed Alarm.
Recovery Period
<reco_time>30</reco_time>
Recovery Period number between the range of 5
60 minutes. It specifies the time between Master
initiated Checkback tests when the UPLC-II™ is in
Recovery Mode.
Loopback Duration
<loop_time>10</loop_time>
Loopback Duration is 4 60 seconds. It specifies
how long a UPLC-II™ will key its transmitter at
high and low power during a Loopback test.
Synchronize Clock Automatically
<sync_enab>1</sync_enab>
Synchronize Clock Automatically is a single digit
value. Only 0 or 1 is valid:
1 – Enable Automatic Synchronization
0 – Disable Automatic Synchronization

Table of Contents