Configuring Communication
64
NXD/T-1200V Wall/Flush Mount Touch Panel
4. Do not alter the IP Settings section, of the System Settings page, as these fields are not applicable to this connection
mode.
5. Enter a username and password (into their respective fields) if the target Master has been previously secured.
6. Press the on-screen Reboot button to both save any changes and restart the panel.
7. Press the grey Front Setup Access button for 3 seconds to open the Setup page and confirm there is an active
connection.
Using G4 Web Control to Interact with a G4 Panel
The G4 Web Control feature allows you to use a PC to interact with a G4 enabled panel via the web. This feature works
in tandem with the new browser-capable NetLinx Security firmware update (build 300 or higher). G4 Web Control is
only available with the latest Modero panel firmware.
Refer to the G4 Web Control Page section on page 94 for more detailed field information.
1. Press the grey Front Setup Access button for 3 seconds to open the Setup page.
2. Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup page and
display an on-screen keypad.
3. Enter 1988 into the Keypad’s password field (1988 is the default password).
4. Press Done when finished.
5. Press the G4 Web Control button to open the G4 Web Control page (FIG. 67).
6. Press the Enable/Enabled button until it toggles to Enabled (light blue color).
7. The Network Interface Select field is read-only and displays the method of communication to the web. Verify you
have selected the proper interface connection as this field does not auto-detect the connection type being used
(see below).
The NetLinx Master and the Modero panel must both be on the same Subnet.
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest
firmware KIT file from www.amx.com. Refer to your NetLinx Master Instruction
Manual for more detailed information on the use of the new web-based NetLinx
Security.
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.
FIG. 67 G4 Web Control page