1-4 Calibration and Verification General Information
1-6 PN: 10580-00444 Rev. U MS2090A UG
Disconnecting Procedure
1. If a wrench is needed, use an open-end wrench to keep the connector body from turning while loosening
with a second wrench.
2. Complete the disconnection by hand, turning only the connector nut.
3. Pull the connectors straight apart without twisting or bending.
ESD Caution
The Field Master Pro, like other high performance instruments, is susceptible to electrostatic discharge (ESD)
damage. Coaxial cables and antennas often build up a static charge, which (if allowed to discharge by
connecting directly to the instrument without discharging the static charge) may damage the Field Master Pro
input circuitry. Instrument operators must be aware of the potential for ESD damage and take all necessary
precautions.
Operators should exercise practices outlined within industry standards such as JEDEC-625 (EIA-625),
MIL-HDBK-263, and MIL-STD-1686, which pertain to ESD and ESDS devices, equipment, and practices.
Because these apply to the Field Master Pro, it is recommended that any static charges that may be present be
dissipated before connecting coaxial cables or antennas to the instrument. This may be as simple as
temporarily attaching a short or load device to the cable or antenna prior to attaching to the Field Master Pro.
It is important to remember that the operator may also carry a static charge that can cause damage. Following
the practices outlined in the above standards will ensure a safe environment for both personnel and
equipment.
1-4 Calibration and Verification
The Field Master Pro comes fully calibrated from the factory and there are no field-adjustable components.
Anritsu recommends annual calibration and performance verification by local Anritsu service centers.
Accredited calibration to ISO17025 and ANSI/NCSL Z540-1 are available and can include a calibration
certificate, test report, and uncertainty data. Contact Anritsu sales and service centers for more information.
1-5 Contacting Anritsu for Sales and Service
To contact Anritsu, visit the following URL and select the services in your region:
http://www.anritsu.com/contact-us

Table of Contents

Other manuals for Anritsu Field Master MS2070A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu Field Master MS2070A and is the answer not in the manual?

Anritsu Field Master MS2070A Specifications

General IconGeneral
BrandAnritsu
ModelField Master MS2070A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals