4-14 [:SENSe] Subsystem Spectrum Analyzer Commands
4-58 PN: 10580-00319 Rev. N S412E PM
[:SENSe]:CORRection:IMPedance[:INPut]:OFFSet <rel ampl>
[:SENSe]:CORRection:IMPedance[:INPut]:OFFSet?
Title: Other Input Impedance Loss
Description: Sets the value that is used for amplitude correction when the value set
by [:SENSe]:CORRection:IMPedance[:INPut][:MAGNitude] is
something other than 50 or 75. This value is not applied if the
impedance is set to either 50 or 75.
Parameter: <rel ampl>
Default Value: 0
Default Unit: dB
Range: 0 dB to 100 dB
Related Command: :CORRection:IMPedance[:INPut][:MAGNitude]
Front Panel Access: Shift-8 (System), Application Options, Impedance
[:SENSe]:CORRection:IMPedance[:INPut][:MAGNitude] <integer>
[:SENSe]:CORRection:IMPedance[:INPut][:MAGNitude]?
Title: Input Impedance
Description: Sets the input impedance that is used for amplitude correction and
conversion between units (dBm vs. dBV vs. Volts, etc.). If the value of
<integer> is 50 no correction is performed. If the value of <integer> is 75
correction is done based on Anritsu adapter 12N50-75B.
Parameter: <integer>
Parameter Type: <integer>
Default Value: 50
Range: 50, 75 all other values are treated as described above
Related Command: :BANDwidth|BWIDth:VIDeo:RATio
Front Panel Access: Shift-8 (System), Application Options, Impedance