4-14 [:SENSe] Subsystem Spectrum Analyzer Commands
4-62 PN: 10580-00319 Rev. N S412E PM
[:SENSe]:FSTRength:ANTenna <antenna>
[:SENSe]:FSTRength:ANTenna?
Title: Field Strength Antenna
Description: Selects an antenna from the antenna list to use for field strength
measurement result calculations. The <antenna> argument is a 1-based
index of the position of the desired antenna in the instrument’s current
antenna list. The list can be displayed on the instrument by choosing
the “Antenna” submenu button in the “F Strength” menu. For example,
if the desired antenna were the 3rd item on the antenna listing then the
value of the <antenna> argument would be 3.
The query form of this command will return the index of the currently
selected antenna.
Parameter: <antenna>
Default Value: 1
Related Command: :CONFigure:FSTRength
Front Panel Access: Shift-4 (Measure), Field Strength, Antenna
[:SENSe]:FSTRength:STATe OFF|ON|0|1
[:SENSe]:FSTRength:STATe?
Title: Field Strength Measurement State
Description: Sets the state of the field strength measurement, ON or OFF. When
using :CONFigure:FSTRength, the state is automatically set to ON.
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: OFF
Related Command: :CONFigure:CHPower
Front Panel Access: Shift-4 (Measure), Field Strength, On/Off
Note An invalid selection will return a zero when queried.