LTE Commands 9-11 [:SENSe] Subsystem
S412E PM PN: 10580-00319 Rev. N 9-23
[:SENSe]:CELLID <char>
[:SENSe]:CELLID?
Title:
Cell ID
Description:
Sets the Cell ID value used when Sync Type is set to ‘RS’.
Parameter:
(the known Cell ID)
Parameter Type:
<char>
Front Panel Access:
Setup, Sync (RS), Cell ID
[:SENSe]:EMF:STATe OFF|ON|0|1
[:SENSe]:EMF:STATe?
Title:
EMF State
Description:
Switches EMF ON or OFF.
The query form of this command returns a 0 or 1 when EMF state is
OFF or ON, respectively.
Note: EMF will turn ON only if the start and stop frequencies are
within the frequency range of the signal analyzer and isotropic antenna
used. The antenna must be connected.
Parameter:
OFF|ON|0|1
Parameter Type:
<boolean>
Default Value:
OFF
Front Panel Access:
Measurements, Over-the-Air, EMF
[:SENSe]:EVM:MODe AUTO|PBCHonly
[:SENSe]:EVM:MODe?
Title:
Set EVM Mode
Description:
Sets/Returns the EVM Mode to either Auto or PBCH Only.
Parameter:
AUTO|PBCHonly
Parameter Type:
<char>
Default Value:
AUTO
Front Panel Access:
Setup, EVM Mode

Table of Contents