13-13 [:SENSe] Subsystem dPMR Commands
13-38 PN: 10580-00319 Rev. N S412E PM
[:SENSe]:FREQuency:COUPling:OFFSet <value>
[:SENSe]:FREQuency:COUPling:OFFSet?
Description: Sets the frequency coupling offset. If frequency coupling is on, the
Tx frequency will automatically trail the Rx frequency by this amount.
Please note that the instrument will prevent any coupling offset setting
that will make the Tx frequency go beyond the min/max values.
The query returns the current coupling offset in Hz.
Cmd Parameters: <Value>
Query Parameters: NA
Range: -1000000000 Hz to 1000000000 Hz
Default Value: 0 Hz
Default Unit: Hz
Example: To set coupling offset to 200 MHz:
:SENSe:FREQuency:COUPling:OFFSet 200000000
Front Panel Access: Frequency, Coupling Offset
[:SENSe]:FREQuency:SPAN 25|50|100|500|1000|5000
[:SENSe]:FREQuency:SPAN?
Description: Sets the span of the Spectrum display in dPMR Analyzer measurement
mode.
Note: Span value is set and returned in kHz.
Cmd Parameters: 25|50|100|500|1000|5000
Query Parameters: NA
Range: 25|50|100|500|1000|5000
Default Value: 25
Default Unit: kHz
Example: To set the span to 1 MHz:
:SENSe:FREQuency:SPAN 1000
Front Panel Access: Frequency, Span

Table of Contents