DMR 2 Commands 14-2 :CONFigure Subsystem
S412E PM PN: 10580-00319 Rev. N 14-3
:CONFigure:BITCap
Description: This command configures the DMR 2 Bit Capture measurement.
Certain settings from the previous measurement (Ref Lvl, Scale, Graph
Types, Maximize) will be backed up when exiting this measurement and
restored when entering this measurement. All other settings carry over
from one measurement to the other. Please note that you must have the
Rx pattern set to VOICe to set the DMR 2 Bit Capture measurement.
Cmd Parameters: NA
Query Parameters: NA
Range: NA
Default Value: NA
Default Unit: NA
Example: To switch the measurement to DMR 2 Bit Capture:
:CONFigure:BITCap
Related Command: :DM:PATTern VOICe
Front Panel Access: Measurement, DMR 2 Bit Capture
:CONFigure:COVerage
Description: This command configures the DMR 2 Coverage measurement. Certain
settings from the previous measurement (Mapping Type) will be backed
up when exiting this measurement and restored when entering this
measurement. All other settings carry over from one measurement to
the other.
Cmd Parameters: NA
Query Parameters: NA
Range: NA
Default Value: NA
Default Unit: NA
Example: To switch the measurement to DMR 2 Coverage:
:CONFigure:COVerage
Front Panel Access: Measurement, DMR 2 Coverage