EasyManua.ls Logo

Anritsu LMR Master S412E - Page 51

Anritsu LMR Master S412E
704 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spectrum Analyzer Commands 4-2 :CALCulate Subsystem
S412E PM PN: 10580-00319 Rev. N 4-9
:CALCulate:LIMit:TYPe 0|1
:CALCulate:LIMit:TYPe?
Title: Set Limit Line Upper or Lower
Description: Sets the currently active limit line to either upper or lower. Subsequent
limit line operations will be performed on the selected limit line.
Parameter: 0|1 (0 = upper limit line, 1 = lower limit line)
Parameter Type: number
Default Value: 0 (upper)
Range: 0|1
Example: To set the active limit line to upper:
:CALCulate:LIMit:TYPe 0
Related Command: :None
Front Panel Access: Shift-6 (Limit), Limit
:CALCulate:LIMit:UPPer:ALARm OFF|ON|0|1
:CALCulate:LIMit:UPPer:ALARm?
Title: Upper Limit Alarm
Description: Enables/disables the alarm for the upper limit. It is a combination of the
commands :CALCulate:LIMit:TYPe 0 and :CALCulate:LIMit:ALARm
ON|OFF. Setting the value to ON or 1 will turn on the upper limit
alarm. Setting the value to OFF or 0 will turn off the upper limit alarm.
The query version of the command returns a 1 if the upper limit line
alarm is ON and returns 0 if OFF.
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: OFF
Related Command: :CALCulate:LIMit:ALARm
Front Panel Access: Shift-6 (Limit), Limit Alarm
:CALCulate:LIMit:UPPer:FAIL?
Title: Upper Limit Fail State
Description: Query whether the upper limit line has failed or not. The command
returns a 0 on success, 1 on fail, and 2 if the upper limit line is OFF or
the alarm is OFF.

Table of Contents

Related product manuals