4-9 :MMEMory Subsystem Spectrum Analyzer Commands
4-34 PN: 10580-00319 Rev. N S412E PM
:MMEMory:STORe:LIMit <file name>
Title: Save Limit
Description: Stores the current limit setup into the file specified by <file name>. <file
name> should be enclosed in either single quotes (‘ ’) or double quotes (“
”) and should not contain a file extension. Use the command
MMEMory:MSIS to set the current save location.
Parameter: <file name>
Related Command: :MMEMory:MSIS INTernal|USB
Front Panel Access: Shift-7 (File), Save
:MMEMory:STORe:STATe <integer>,<file name>
Title: Save Setup
Description: Stores the current setup into the file specified by <file name>. <file
name> should be enclosed in either single quotes (‘ ’) or double quotes (“
”) and should not contain a file extension. Use the command
MMEMory:MSIS to set the current save location. The <integer>
parameter is not currently used, but it must be sent. Send a value of 0.
Parameter: <integer>, <file name>
Related Command: :MMEMory:LOAD:STATe
:MMEMory:MSIS INTernal|USB
Front Panel Access: Shift-7 (File)
:MMEMory:STORe:TRACe <integer>,<file name>
Title: Save Measurement
Description: Stores the trace into the file specified by <file name>. <file name>
should be enclosed in either single quotes (‘ ’) or double quotes (“ ”) and
should not contain a file extension. Use the command MMEMory:MSIS
to set the current save location. The <integer> parameter is not
currently used, but it must be sent. Send a 0.
Parameter: <integer>, <file name>
Example: To save the trace into the file name “trace”:
:MMEMory:STORe:TRACe 0,”trace”
Related Command: :MMEMory:LOAD:TRACe
:MMEMory:MSIS INTernal|USB
Front Panel Access: Shift-7 (File), Save