4-14 [:SENSe] Subsystem Spectrum Analyzer Commands
4-56 PN: 10580-00319 Rev. N S412E PM
[:SENSe]:BANDwidth|BWIDth[:RESolution] <freq>
[:SENSe]:BANDwidth|BWIDth[:RESolution]?
Title: Resolution Bandwidth
Description: Sets the resolution bandwidth. Note that using this command turns the
automatic resolution bandwidth setting OFF.
Parameter: <freq>
Default Value: 3 MHz
Default Unit: Hz
Range: 10 Hz to 3 MHz in a 1:3 sequence except for the MS2711E
100 Hz to 3 MHz in a 1:3 sequence for the MS2711E
Related Command: :BANDwidth|BWIDth[:RESolution]:AUTO
Front Panel Access: BW, RBW
[:SENSe]:BANDwidth|BWIDth[:RESolution]:AUTO OFF|ON|0|1
[:SENSe]:BANDwidth|BWIDth[:RESolution]:AUTO?
Title: Resolution Bandwidth Coupling
Description: Sets the state of the coupling of the resolution bandwidth to the
frequency span. Setting the value to ON or 1 will result in the resolution
bandwidth being coupled to the span. That is, when the span changes,
the resolution bandwidth changes. Setting the value to OFF or 0 will
result in the resolution bandwidth being un-coupled from the span.
That is, changing the span will not change the resolution bandwidth.
When this command is issued, the resolution bandwidth setting itself
will not change. The default value is ON. That is, sending
:SENS:BAND:RES:AUTO is equivalent to sending
:SENS:BAND:RES:AUTO ON.
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: ON
Related Command: [:SENSE]:BANDwidth|BWIDth[:RESolution]:RATio
Front Panel Access: BW, Auto RBW