Anybus Module Objects 107 (258)
Command Details: Reset
Category
Details
Command Code: 05h
Valid for: Object Instance
Description
A reset command to this object will result in that all instances are set to their default values.
It is optional to implement support for this command.
• Command Details
Field Comments
CmdExt[0] 00h (Reserved)
CmdExt[1] 01h (Factory default reset)
• Response Details
(No data)
Anybus
®
CompactCom
™
40 PROFINET IRT Network Guide SCM-1202-023 EN 1.8