AUMA ACVExC 01.2 Series User Manual

AUMA ACVExC 01.2 Series
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Control
Parallel
Profibus
Modbus RTU
Modbus TCP/IP
Foundation Fieldbus
HART
Actuator controls
ACV 01.2/ACVExC 01.2
Operation and settingManual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the AUMA ACVExC 01.2 Series and is the answer not in the manual?

AUMA ACVExC 01.2 Series Specifications

General IconGeneral
Type of ProtectionEx d
Voltage24V DC, 110-230V AC
Control functionsOpen-close, Modulating
CommunicationModbus, Profibus, Foundation Fieldbus
Housing materialAluminum
Protection classIP67

Summary

Safety Instructions

Basic Information on Safety

Covers standards, directives, and qualifications for safe operation and compliance.

Range of Application

Defines the intended use and limitations of AUMA actuator controls.

Basic Settings for Commissioning

Type of Seating for End Positions

Configuring actuator shut-off at end positions via limit or torque switching.

Torque Switching

Setting overload protection and tripping torques for actuator end positions.

Application Functions

Speed Functions

Configuring actuator speed for local and remote operation modes.

Intermediate Positions (Pivot Points)

Setting and configuring up to 8 intermediate positions for actuator travel.

Failure Functions

Reversing Prevention Time

Prevents restart for a defined interval after motor switch-off.

Failure Behaviour on Loss of Signal

Defines actuator response to signal loss in remote operation modes.

EMERGENCY Behaviour

Configures actuator response to an EMERGENCY signal for safe operation.

Monitoring Functions

Torque Monitoring

Monitors torque to prevent overload and detect warnings.

Motor Protection Monitoring (Thermal Monitoring)

Monitors motor temperature to prevent overheating and ensure safety.

Type of Duty Monitoring (Motor Starts and Running Time)

Monitors permissible motor starts and running time per hour.

Functions: Activate and Enable

Activate Functions

Enables or disables specific application functions via menu.

Enable Functions

Optional function enabling/disabling based on user level and settings.

Service Functions

Direction of Rotation

Allows changing the motor rotation direction for actuators with 3-phase AC motors.

Factory Setting

Generates new factory settings or restores former settings.

Diagnostics

Electronic Device ID

Provides order data, device designation, versions, and identification.

Diagnostic Bluetooth Connection

Checks the status of the Bluetooth connection for diagnostics.

Diagnostic Interface

Checks configuration and state of input/output signals and interface status.

Plant Asset Management

Operating Data

Collects and analyzes operational data like running time, starts, and faults.

Event Report

Records and exports system events, status signals, and operational data.

Characteristics

Displays torque-travel, position-time, and temperature-time characteristics.

Corrective Action

Primary Fuses

Instructions for exchanging primary fuses in actuator controls.

Fault Indications and Warning Indications

Interpreting and responding to fault and warning messages on the display.

Appendix

Selection Overview for Output Contacts and Indication Lights (Digital Outputs DOUT)

Maps digital output signals to their descriptions and functions.

Selection Overview of Binary Signals for Digital Inputs (DIN)

Maps digital input signals to their descriptions and functions.

Related product manuals