Variable Value
zone Specifies time zone acronym that can be displayed
when showing system time; for example, EST for
Eastern Standard Time.
RANGE: Up to 4 characters
hours Specify the hours difference from UTC.
RANGE: —12 to + 12
minutes Optional minutes difference from UTC.
RANGE: 0–59
no Disables the clock time zone feature
Setting or disabling daylight savings time
Set the daylight savings time with start and end dates, or disable the daylight savings time feature.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
[no] clock summer-time <zone> [date {<day> <month> <year> <hh:mm>}
{<day> <month> <year> <hh:mm>}] [<offset>]
Variable definitions
The following table describes the parameters for the clock summer-time command.
Variable
Value
zone Specifies the acronym to be displayed when summer
time is in effect. If unspecified, defaults to the time
zone acronym.
RANGE: up to 4 characters
date {<day> <month> <year> <hh:mm>} {<day>
<month> <year> <hh:mm>}
The first date specifies when summer time starts,
and the second date specifies when summer time
ends.
day — day of the month (RANGE: 1 to 31)
month — month (RANGE: first three letters by
name)
hh:mm — time in military format (24–hour clock), in
hours and minutes
Table continues…
Configuring the switch using ACLI
July 2015 Getting Started with Avaya ERS 3500 Series 73