Installing and wiring telephones and trunks
Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway 197
December 2003
Figure 77: 400B2 Adapter connecting to a modular plug
Connecting an analog station or 2-wire digital
station
This example is typical of the 2-wire digital stations (2420, 64xx, 302D), 2-wire analog stations (2500),
analog central office (CO) trunks, direct inward dial (DID) trunks, and external alarms. See Figure 78,
2500-type analog telephone wiring, on page 198.
1 Choose a peripheral to connect (such as a 2-wire digital station).
2 Choose the media module to use and its media gateway and slot number. For example: MM711
Analog Media Module, Media Gateway 002, Slot V2.
3 Choose a port circuit on the MM711 Media Module, for example port 03.
4 Install cross-connect jumpers to connect the pins from the 2-wire digital station to the appropriate
pins on the MM711 Media Module. Table 15, Station pinout chart,
on page 198 shows a printout
chart for two-wire stations.
5 Administer using Administrator’s Guide for Avaya Communication Manager.
Figure notes
1 Flush-Mounted Information Outlet
2 Surface-Mounted Information Outlet
3 To Individual Power Unit
4 400B2 Adapter
5 To Telephone
6 Destination Service Access Point (DSAP)
Power Cord
r749428 KLC 060396