EasyManua.ls Logo

Avaya S8700 - Connecting the 1152 A1 Power Distribution Unit; Connecting the Cables; Using the 1152 A1 Power Distribution Unit

Avaya S8700
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing and wiring telephone power supplies
238 Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway
December 2003
If it exhibits a distinct change in performance.
If it does not operate normally when following the operating instructions.
Using the 1152A1 Power Distribution Unit
The 1152A1 PDU is used to power the 46xx series of IP telephones in addition to providing 10/100
megabits per second Ethernet connection.
Generation 1 Avaya IP telephones can receive power from the 1152A1 via an in-line adapter. This adapter
provides the resistive signature so that the 1152A1 allows power to flow to the telephone. The generation
2 telephones do not need an adapter.
The 1152A1 PDU has 24, 10/100 Base-T ports, each can supply up to 16.8 watts using the internal power
supply and operates on a 100-240 VAC, 60/50 hertz power source.
The 1152A1 PDU is 1U high and fits in most standard 19-inch (48-centimeter) racks. It also can be
mounted on a shelf. See the users guide that comes with the unit for complete installation instructions.
Perform these tasks in order:
Connecting the 1152A1 Power Distribution Unit on page 238
Connecting the cables on page 238
Connecting the 1152A1 Power Distribution
Unit
CAUTION:
The 1152A1 PDU has no ON/OFF switch. To connect or disconnect power to the
1152A1 PDU, simply insert or remove the power cable from the AC power receptacle on
the rear of the 1152A1 PDU.
1 Plug a power cord into the power socket on the rear of the 1152A1 Power Distribution Unit.
2 Plug the other end of the power cord into the power receptacle.
The 1152A1 PDU powers up, and the internal fans begin operating.
The 1152A1 PDU then runs through its Power On Self Test (POST), which takes less than 10 seconds.
During the test, all the ports on the unit are disabled and the LEDs light up. For more information on the
test, see the users guide that comes with the unit.
Connecting the cables
All of the ports on the front of the 1152A1 PDU are configured as data route-through ports for all data
wires (pins 1, 2, 3 and 6).
AC
Console
12
3456
13 14
15 16 17 18
19 20
21 22 23 24
78
9 101112
1152A1 Power
Distribution Unit
Data &
Power
Data
48Vdc

Table of Contents