Installing and wiring telephones and trunks
202 Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway
December 2003
Table 16: DS1 cables
Connector cable Description and usage
C6C connector cable 50-feet (15 meters) shielded cable equipped with a 50-pin male
connector on one end and a 15-pin male connector on the other end.
Use this cable to connect a DS1 tie trunk circuit pack to a CSU.
C6D connector cable 50-feet (15 meters) shielded cable equipped with a 50-pin male
connector on each end.
Use this cable to connect a DS1 tie trunks in collocated cabinets.
C6E connector cable 100-feet (31 meters) shielded cable equipped with a 50-pin male
connector on one end and a 50-pin female connector on the other end.
Use this cable as an “extension” cable between the DS1 tie trunk
circuit pack and other connector cables.
C6F connector cable 50-feet (15 meters) shielded cable equipped with a 50-pin male
connector on one end and a 3 inch (8 centimeter) stub on the other
end.
Use this cable to connect the DS1 tie trunk circuit pack to channel
multiplexers requiring hardwired connections.
Table 17: Pinout of C6F cable
Wire color
Lead
designation
Pin
number
White/Green L
I* (High Side) 47
Green LI 22
White/Brown LO 48
Brown LO* (High Side) 23
White/Slate LBACK2 49
Slate LBACK1 24