Installing and wiring telephones and trunks
Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway 215
December 2003
Figure 84: Connections for 1 to 8 out-of-building analog telephones
Figure notes
1 Locally Engineered Cables and Equipment
2 Out-of-Building Wiring
3 25-Pair Connector
4 Multi-Pair Protector Units (Primary Protectors
with Heat Coils or Equivalent with Sneak Current
Protection)
5 356A Adapter
6 B25A Cable (Male to Female)
7 Out-Of-Building Analog Telephones
8 Part of Main Distribution
Frame (MDF)
9 Station Side
10 Media Gateway Side
11 White Field
12 Purple Field
13 Cross-Connect Jumpers
14 Tip and Ring Wires
15 To Analog Line Circuit Pack
8
7
1
9
10
11
13
14
12
crdfobt CJL 101396
2
4 4
6
6
5
3
3