252
Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Installing and Wiring Telephones
May 2003
Install External Ringing
Connections for external ringing are at an information outlet. The media gateway side of the
Main Distribution Frame (MDF) is connected to a TN2183 (or equivalent) Analog Line circuit
pack. The circuitry and power source for the device are provided by the customer.
NOTE:
A maximum of 3 devices can connect to 1 analog line circuit pack port.
1 Wire the ringing device to the information outlet as shown in ‘3-Pair and 4-Pair
Modularity’’ on page 252 and ‘Example Adjunct Power Connections’’ on page 229.
2 Administer per the Administrator’s Guide for Avaya™ Communication Manager.
3-Pair and 4-Pair Modularity
Figure notes
1 Port Circuit Pack
2 Media Gateway Connector Pins
(3-Pair Modularity)
3 Main Distribution Frame (MDF)
Pins (3-Pair Modularity)
4 Input to Information Outlet
(4-Pair Modularity)
5 Adjunct Power
6 Output From Information Outlet
(4-Pair Modularity)
7 Voice or Data Terminal Pins

Table of Contents