Operation
52
F-FEM-DDC Users Guide
4.8.4
Digital Outputs Relay X51, X52
Pin assignment for digital outputs relay X51, X52:
NO … normal open contact (working contact)
NC … normal closed contact
*) The total current for X51 and X52 is limited to 2.0 A for each connector.
Fig. 28
Information
The D-SUB jacks are equipped with a quick lock™ option for an easy click &
mount and a one hand remove mechanism.
Pin Signal at X51 Signal at X52
1 24 V out *) 24 V out *)
9 COMM_X51 COMM_X52
2 24 V out *) 24 V out *)
10 Ch1 NO Ch1 NO
3 Ch1 NC Ch1 NC
11 Ch2 NO Ch2 NO
4 Ch2 NC Ch2 NC
12 Ch3 NO Ch3 NO
5 Ch3 NC Ch3 NC
13 Ch4 NO Ch4 NO
6 Ch4 NC Ch4 NC
14 Shield Shield
7 GND_24 out GND_24 out
15
8 GND_24 out GND_24 out
Case Shield Shield
Tab. 19
Information
The maximum cross section of a wire soldered to a D-SUB connector pin is
limited to 0.5 mm² (equivalent to AWG 20 or more).