Transfer characteristic: input and output voltages vs. time:
In the following section the usage, parameterization and connection with
different sensors or signals is shown.
5.4.4
Parameterization
Depending on the number of tracks (one or two tracks) you must set the sensor
attribute (S.Attr.) accordingly. Please refer to the F-FEM Parameter Manual.
A zero track evaluation is not supported. If you have a sensor with zero track you
can connect it like track A and parameterize it like track A.
Using the adapter together with F-FEM-DDC:
Independent of the used sensor, the F-FEM-DDC counter input must be
parameterized to sensor type (S.Type) "Digital In".
Using the adapter together with F-FEM-CON or -CNT:
If you use this adapter together with an F-FEM-CON or an F-FEM-CNT you
must parameterize a sensor type (S.Type) "Digital In" too.
Fig. 47