© AXION TECHNOLOGIES LTD. INSTALLATION
● Size of the sign in terms of lines and columns.
Whenever the sequence does not start, refer to Section 1.1.1.8.7 Activating Automatic Test
Modes in the OSCP Operation & Parts Manual.
2.5.2. STEP 2: DISTRESS (EMERGENCY) SWITCH TEST (IF INSTALLED)
Check correct functioning of the distress switch (If installed). Turn on Emergency Switch and
check that signs display the distress signal. Enter "00" on the OSCP to deactivate the
emergency mode.
2.5.3. STEP 3: YIELD SWITCH TEST (IF INSTALLED)
Check correct functioning of the Yield Switch (If installed). Turn on momentarily Yield Switch
and check that Rear sign displays the YIELD message for at least 12 seconds.
2.5.4. STEP 4: PHOTOSENSOR LIGHT INTENSITY CONTROL
Check the Intensity checkbox to run photosensor test (See Section 1.1.1.7.2 Activating Signs
Tests in the OSCP Operation & Parts Manual).
Every sign shows a number corresponding to its light intensity level. Check correct
functioning of the light intensity control by blocking or allowing light to the sensor. The
Destination Sign decreases/increases light intensity accordingly. Otherwise, refer to Section
5.1.3 to find the cause.
2.5.5. STEP 5: OFF DELAY FUNCTIONALITY TEST
Check correct functioning of the OFF delay. The factory programmed value is one minute.
Follow the following steps:
● Turn off the Master Run Switch of the bus.
● Wair for one minute to confirm that the EDSS turns off.
User Manual (Revision A) Document No.: 3042145 Page 22