© AXION TECHNOLOGIES LTD. TROUBLESHOOTING
5.2.3. SIGN IDENTITY ERROR MESSAGE
FLASHING 'I'' ON LCD
INDICATES THAT IDENTITY OF SIGN PRESENT ON NETWORK DIFFERS FROM THAT
CONFIGURED ON CONTROL CONSOLE
CHECK PASSES FAILS/CORRECTIVE ACTION
STEP 1
Go to Menu 13 to find out which sign
has an identity problem (See Section
4.1.1.9)
GO TO STEP
2
STEP 2
Reconfigure Sign Network (See
Section 4.1.1.9, Menu 1)
5.2.4. SIGN DATABASE ERROR MESSAGE
FLASHING 'D'' ON LCD
INDICATES THAT THE CONTROL CONSOLE CONFIGURATION DIFFERS FROM THE
DATABASE CONFIGURATION
CHECK PASSES FAILS/CORRECTIVE ACTION
STEP 1
Go to Menu 13 to find out which sign
has an identity problem (See Section
4.1.1.9)
GO TO STEP
2
STEP 2
Download database corresponding to
the sign network configuration or
reconfigure the Control Console
5.2.5. PHOTOSENSOR ERROR MESSAGE
FLASHING ''P'' ON LCD
INDICATES A PHOTOSENSOR ERROR WITH ONE OR MORE SIGNS
CHECK PASSES FAILS/CORRECTIVE ACTION
STEP 1
Go to Menu 13 to find out which
sign(s) has (have) a photosensor
problem (See Section 4.1.1.9)
GO TO STEP
2
STEP 2
Go to Section 5.1.3 and conduct "Light
intensity does not change with ambient
light variations" procedure
User Manual (Revision A) Document No.: 3042145 Page 52