© AXION TECHNOLOGIES LTD. OPERATION
4.1.2.5. PHOTOSENSOR ERROR ("P" SYMBOL)
The photosensor error shows that the photosensor of one or more signs is faulty. LED
intensity cannot change according to ambient light conditions. Faulty sign(s) displays
(display) on the Control Console LCD. Location of the flashing "P" letter shows which of the
signs are faulty. The following figure shows an example of photosensor error on the Rear
Sign.
4.1.2.6. OPERATING FREQUENCY ERROR ("C" SYMBOL)
This error shows that the operating frequency of one or more signs differs from that of the
Control Console. Faulty sign(s) displays (display) on the Control Console LCD. Location of
the flashing "C" letter shows which of the signs are faulty. The following figure shows an
example of the operating frequency error on the Rear Sign.
4.1.2.7. ERROR PRIORITY
The errors present on sign network have a display priority. If a sign has more than one error
code, only one shows at a time. In the order, the display priority of error codes is as follows:
User Manual (Revision A) Document No.: 3042145 Page 42
Figure 32: Photosensor Error
Figure 33: Operating Frequency Error
--- --- C --- --- --- --- --- ---
FT NS RR SD RS KN PI A1 A2
FRONT NEXT
STOP
PUBLICROUTE
REAR
CURB
SIDE
KEY NO. AUX-1 AUX-2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axion 40 Series and is the answer not in the manual?

Axion 40 Series Specifications

General IconGeneral
BrandAxion
Model40 Series
CategoryControl Unit
LanguageEnglish