© AXION TECHNOLOGIES LTD. TROUBLESHOOTING
5.3.4. PHOTOSENSOR ERROR MESSAGE
DISPLAYED IN THE OSCP TASK BAR
INDICATES A PHOTOSENSOR ERROR WITH ONE OR MORE SIGNS
CHECK PASSES FAILS/CORRECTIVE ACTION
STEP 1
Go to Erreur : source de la référence
non trouvée Erreur : source de la
référence non trouvée to find out
which sign(s) has (have) a
photosensor problem (See Section
Erreur : source de la référence non
trouvée)
GO TO STEP
2
STEP 2
Go to Section 5.1.3 and conduct "Light
intensity does not change with ambient
light variations" procedure
5.3.5. SIGN OPERATING FREQUENCY ERROR MESSAGE
DISPLAYED IN THE OSCP TASK BAR
INDICATES THAT THE SIGN PRESENT ON THE NETWORK DOES NOT SUPPORT THE
OPERATING FREQUENCY CONFIGURED ON THE OSCP
CHECK PASSES FAILS/CORRECTIVE ACTION
STEP 1
Go to Erreur : source de la référence
non trouvée Erreur : source de la
référence non trouvée to find out
which sign has a frequency problem
(See Section Erreur : source de la
référence non trouvée)
GO TO STEP
2
STEP 2
Reset signs operating frequency to
Freq 1.. Reconfigure sign network
(See SectionErreur : source de la
référence non trouvée)
User Manual (Revision A) Document No.: 3042145 Page 57

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axion 40 Series and is the answer not in the manual?

Axion 40 Series Specifications

General IconGeneral
BrandAxion
Model40 Series
CategoryControl Unit
LanguageEnglish