19. Start Pulse Generator
19.2 Troubleshooting
Lamp fails to ignite after y ou switched the proje ctor from standby to operation
Situation Solution
You can hea r the SPG modu le three times clicking in an attempt to ignite
the lamp. T he v oltage on the “LA MP OUT” pins of the L PS module is
rst 140 volt during the attempt to ignite and then drops to 0 volt.
Note: The ambient noise must be low to hear the SP G clicking in an
attempt to ignite the lamp.
The LPS and SP G seem to work normally but
the lamp is bad. Install another lam p house.
If the problem remains, replace the SPG
module.
You can not hear the SPG module three times clicking in an attempt to
ignite the lamp. The voltage on the “LAMP O UT pins of the L PS mod ule
is rst 140 volt during the attempt to ignite and then drops to 0 volt.
Note: The ambient noise must be low to hear the SP G clicking in an
attempt to ignite the lamp.
Check the c abling of the SPG mo dule.
Replace the SPG module.
You can not hear the SPG module three times clicking in an attempt to
ignite the lamp. The voltage on the “LAMP O UT pins of the L PS mod ule
is below 140 vo lt during the attempt to ignite. The diagnostic LED ’s of
the LP S module indicates a problem w ith the LP S module.
Note: The ambient noise must be low to hear the SP G clicking in an
attempt to ignite the lamp.
Check the c abling of the LPS module.
Replace the LP S module.
R5905043 DP2K-12C/11CX 19/02/2018 305

Table of Contents

Other manuals for Barco DP2K-12C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco DP2K-12C and is the answer not in the manual?

Barco DP2K-12C Specifications

General IconGeneral
BrandBarco
ModelDP2K-12C
CategoryProjector
LanguageEnglish

Related product manuals