Power On Setup Functions Power On Setup
104
Qlarity-Based Terminal Hardware
options. Press [Next] or [Back] to select Develop, then press [Select] to return to the function
name.
Press
[Next] or [Back] to move to the DONE section, and select Save and Exit. The terminal
is ready for the user application to be downloaded.
Download the application through the serial or Ethernet port interface using the “Download
Application” function in Qlarity Foundry (refer to the Qlarity Foundry User's Manual for
instructions). (If you use an Ethernet port, make sure you have selected the proper network set-
tings; see section 8.4.4.)
While the terminal is in “Develop” mode, a user application downloaded to the terminal is not
saved in flash memory. This saves unnecessary wear on the flash memory and speeds up
download time while testing an application in development. However, the application is
removed when the terminal is powered off.
If you previously downloaded an application using the “App Mode: Download” function, that
application remains in flash memory (it is not overwritten by an application downloaded while
in develop mode). This makes it possible to test a new application without copying over an
existing application.
Press
[Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power
On Setup.
Run App:
Select this option to set the terminal to the “Run App” operational mode. If the terminal is in
“Run App” mode and a user application was saved in flash memory, the application runs when
the terminal is powered on.
Press
[Next] or [Back] to move to FLASH MEMORY. Press [Select] and then [Next] to move
to
App Mode, and press [Select] again to move to the options. Press [Next] or [Back] to select
Run App, then press [Select] to return to the function name.
Press
[Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power
On Setup.
Run Default:
Select this option to set the terminal to the “Run Default” operational mode. If the terminal is
in “Run Default” mode, the default application associated with the firmware runs when the ter-
minal is powered on. Not all firmware builds have a default application. Press
[Next] or [Back]
to move to
FLASH MEMORY. Press [Select] and then [Next] to move to App Mode, and press
[Select] again to move to the options. Press [Next] or [Back] to select Run Default, then press
[Select] to return to the function name.
Press
[Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power
On Setup.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beijer Electronics QTERM-G70 and is the answer not in the manual?

Beijer Electronics QTERM-G70 Specifications

General IconGeneral
BrandBeijer Electronics
ModelQTERM-G70
CategoryTouch terminals
LanguageEnglish

Related product manuals