Power On Setup Functions Power On Setup
118
Qlarity-Based Terminal Hardware
8.4.11.5Addr
Use this function to set the IP address to send UDP packets to for feedback.
Press
[Next] or [Back] to move to FEEDBACK. Press [Select] and [Next] to move to the
“UDP” field. Press
[Select] again to move to the first digit in the “UDP” field. Press [Next] or
[Back] to change the digit's value.
Press
[Select] to move to the next digit and press [Next] or [Back] to change it. Continue to
press
[Select] and change each digit in the address as required. Press [Select] at the last digit
to return to the UDP field.
N
OTE
If you are using a keyboard, you can use the number keys (0-9) to enter the digits.
Press
[Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power
On Setup.
8.4.11.6Port Number
Use this function to set the port number to send UDP feedback packets to.
Press
[Next] or [Back] to move to FEEDBACK. Press [Select] and [Next] to move to the
“Port” field. Press
[Select] again to move to the first digit in the “Port” field. Press [Next] or
[Back] to change the digit's value. Press [Select] to move to the next digit and press [Next] or
[Back] to change it. Continue to press [Select] and change each digit in the Port number as
required. Press
[Select] at the last digit to return to the Port field.
N
OTE
If you are using a keyboard, you can use the number keys (0-9) to enter the digits.
Press
[Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power
On Setup.
8.4.12Miscellaneous
The Miscellaneous functions include the setting up of a password for Power On Setup and also
a unit information display screen.
8.4.12.1Information
Use this function to determine the current version of firmware, current BFF version, minimum
BFF version, amount of RAM, amount of flash memory, the current flash file system size, and
Ethernet MAC address of the unit.
Press
[Next] or [Back] to move to MISCELLANEOUS. Press [Select] to move to Information,
and press
[Select] again to view this data.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beijer Electronics QTERM-G70 and is the answer not in the manual?

Beijer Electronics QTERM-G70 Specifications

General IconGeneral
BrandBeijer Electronics
ModelQTERM-G70
CategoryTouch terminals
LanguageEnglish

Related product manuals