System Management Portfolio 2.0 Product Manual Rev. C, Feb. 2020
Page 19
SMP Hardware General Technical Specifications
ENVIRONMENTAL
Temperature
Operating: 0° to 50°C (32°F to 122°F) Ambient
Storage: -20°C to 70°C (-4°F to 158°F)
Humidity
Operating: 5% to 95%, non-condensing
Storage: Unlimited
Altitude
Operating: Thinklogical components are rated to 1000m max. elevation.
Max. operating temp. de-rates by 3% for every 330m > 1000m
Storage: Unlimited
THERMAL
Heat load (BTU/HR): Equal to DC Power consumption x 3.1412
REGULATORY
US / Canada EN 90650, FCC 47 CFR Part 15, ICES, CE
WARRANTY
One year from date of shipment. Extended warranties available.
All values are absolute maximum.
BTU = Wattage x 3.1412, rounded up to the next 100.