5. Too noisy pump Wrong pump rotation direction
Presence of some air in oil
Oil viscosity causing obstructions to the
suction system
Irregular inflow of oil to the pump, caused
by an insufficient filtering capacity of the
filter (the filter could be dirty or not suitable)
Big lacks of charge along the suction line
Worn pump’s components
Relief valve vibrations
Mechanical vibration due to a bad anchor
action
Verify/Check
Bleed
Verify/Check
Verify/Check/Clean
Verify/Check
Verify/Check/Replace
Verify/Check
Verify/Check
Problem Cause Action