TROUBLESHOOTING
Studio ti 03312 540-04usa
340
15
6. Too high temperature rating The pump is working at a higher pressure
than the allowed one
Faulty or worn pump causing internal blow-
by
Excessive blow-by through valves and
cylinder
Too viscous oil
Continuous overloaded operation
Too high temperature in the room where
the pump unit is placed
Verify/Check
Verify/Check
Verify/Check
Verify/Check
Verify/Check
Verify/Check
7. Leakages by seals Possible abrasive substances entered into
the system and circulating with oil, which
have damaged pump shaft
Seals are faulty, broken or mounted in a
wrong way
Too hot oil
Verify/Check
Verify/Check
Verify/Check
8. Pump overcharged motor Too viscous oil
Obstructed delivery fine or excessive
resistance
Verify/Check
Verify/Check
Problem Cause Action