Status word 411
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bit
0
Ready for activation
1
Active
2
Operation - enabled
3
Fault
4
Voltage - enabled
5
Quick stop (Low active)
6
Activation disabled
7
Warning
8
-
9
Remote
10
Target reached
11
Internal limit value active
12
-
13
-
14
-
15
Warning 2
If operation mode “Control via remote contacts” is used, controller release must be
turned on at STOA (Terminal X210A.3) and STOB (Terminal X210B.2) and
Bit 0 of the
control word must be set in order to be able to start the drive.
Operation modes “Control via contracts” and “Control via remote contacts” support
operation mode “Speed vl” (
modes of operation
= “velocity mode”).
ACTIVE CUBE frequency inverters support an external 24 V power supply for the fre-
quency inverter control electronics. Even when mains voltage is disconnected, co
m-
munication between the controller (PLC) and the frequency inverter is still possible.
Bit 4 “Power supply enabled” of the status word shows the
current mains power
supply status:
Bit 4 “Power supply
enabled” = 0 signals “No mains voltage”, starting of drive not
possible.
Bit 4 “Power supply enabled” = 1 signals “Mains voltage on”, drive ready for star
t-
ing.
10/13 CM-PROFINET 65