internal
set point
refer to note
frequency
ramp
fmax
fmin
0
1
+
line
set point
operation mode 434
ramp set point
The internal reference value from the reference frequency channel and the reference
line value can be f
ed to the ramp individually or as an added variable. The operation
mode of the ramp function is set via the data set switchable parameter Ramp se
434.
1
Internal reference fre-
quency
The internal reference frequency is determined from
the percentage reference value source or the refer-
2
Reference line value
The reference value is supplied externally via the
communication interface.
3
internal + reference line
value
Addition (considering the sign) of internal reference
frequency and reference line value
The Internal reference frequency can be controlled via the frequency inverter with the
control unit KP500 or the control software VPlus, the reference line value is supplied
If Ramp setpoint 434 = 2 (reference line value only), this reference line value is lim-
ited to fmin.
The sign in front of
fmin with reference value = 0 is derived from the sign in front of
the last reference line value which was not 0.
After Mains On, the reference line value is limited to +fmin.
For Ramp setpoint 434 = 3, the sign of the total reference value results from the total
of internal reference frequency and reference line value.
Internal reference fre-
quency 228
Internal reference value from the reference
frequency channel
Reference bus frequen-
cy
282
PROFINET reference line value
Reference ramp frequency
283
= sum of internal reference frequency +
reference line value
10/13 CM-PROFINET 75