11.4.7 Electronic gear: Slave
The mode “Electronic gear: Slave”
can be selected via parameter Override Modes Of
Operation 1454 =-3.
In operation mode “Electronic gear: Slave”, the drive follows a master drive as a slave
drive.
Relevant parameters:
410
Control word
1126
Phasing: Speed
411
Status word
1127
Phasing: Acceleration
418
Minimum Frequency
1108
Act. Position
419
Maximum Frequency
1106
Error Threshold
1454
Override Modes Of Operation
1119
Contouring Error Time
1123
Gear Factor: Numerator
1165
Target window
1124
Gear Factor: Denominator
1166
Target window time
1142
Resync. on Change of Gear-
Factor
1179
Emergency ramp
1125
Phasing: Offset
In operation mode “Electronic gear: Slave”, the mode-specific bits of the control word
and the status word are used as follows:
Control word
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bit
0
Switch on
1
Enable voltage
2
Quick stop (low active)
3
Enable operation
4
Start Gearing
5
Start M/S Correction
6
Direct Sync
7
Fault reset
8
Halt
9
Start phasing
1
0
-
1
1
-
1
2
Phasing switching 0
1
3
Phasing switching 1
1
4
-
1
5
-
10/13
ACU
Modbus/TCP 109

Table of Contents

Other manuals for BONFIGLIOLI Active Cube

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Active Cube and is the answer not in the manual?

BONFIGLIOLI Active Cube Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelActive Cube
CategoryInverter
LanguageEnglish

Related product manuals